2. Common Test Cases

2.1 CMN/EP/API/INF/BV/01: Endpoint has correct MCU version after launching Sidewalk application.

2.1.1 Test Purpose

DUT is able to start Sidewalk application and capture all values related to the MCU version. Captured values are consistent with the MCU build used by the DUT.

2.1.2 Initial Conditions

  • DUT is flashed with a valid MCU build.

2.1.3 Test Procedure

sequenceDiagram
    participant DUT as DUT
    participant Upper_Tester as Upper Tester
    Note over DUT,Upper_Tester: Sidewalk application started
    Upper_Tester->>DUT: sid_version()
    DUT->>Upper_Tester: #35;SID_ERROR_NONE
    DUT->>Upper_Tester: "MAJOR_VERSION", "MINOR_VERSION", "PATCH_VERSION", "BUILD_VERSION"

2.1.4 Expected Results

2.1.4.1 Pass Verdict

DUT can successfully start the Sidewalk application.

DUT is able to utilize sid_version API call and capture the following values related to the MCU version: MAJOR_VERSION, MINOR_VERSION, PATCH_VERSION, BUILD_VERSION.