Attribute Value
Case ID C83934651
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Send 1 DL packet from AWS IoT with 1 byte payload EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: 1, LINK: 4, LINK_MODE: <x>, ACK_REQUESTED: <x>, ACK: <x>, DUP: <x>, RSSI: <x>, SNR: <x> Data: <payload> Key check: Delivery ratio 100%
2 Send 1 DL packet from AWS IoT with 10 bytes payload EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: 10, LINK: 4, LINK_MODE: <x>, ACK_REQUESTED: <x>, ACK: <x>, DUP: <x>, RSSI: <x>, SNR: <x> Data: <payload> Key check: Delivery ratio 100%
3 Send 1 DL packet from AWS IoT with 19 bytes payload EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: 19, LINK: 4, LINK_MODE: <x>, ACK_REQUESTED: <x>, ACK: <x>, DUP: <x>, RSSI: <x>, SNR: <x> Data: <payload> Key check: Delivery ratio 100%

Attribute Value
Case ID C83934652
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Send 1 UL packet from EN with 1 byte payload: sid send <1-byte-payload> CMD: ERR: 0 TYPE: 2 ID: <id> EVENT SID SEND STATUS: SID ERR: 0, TYPE: 2, ID: <id>, LINK: 4 LINK_MODE: 0 ADDITIONAL ATTRS: 0 Key check: Packet received on AWS
2 Send 1 UL packet from EN with 10 bytes payload: sid send <10-byte-payload> CMD: ERR: 0 TYPE: 2 ID: <id> EVENT SID SEND STATUS: SID ERR: 0, TYPE: 2, ID: <id>, LINK: 4 LINK_MODE: 0 ADDITIONAL ATTRS: 0 Key check: Packet received on AWS
3 Send 1 UL packet from EN with 19 bytes payload: sid send <19-byte-payload> CMD: ERR: 0 TYPE: 2 ID: <id> EVENT SID SEND STATUS: SID ERR: 0, TYPE: 2, ID: <id>, LINK: 4 LINK_MODE: 0 ADDITIONAL ATTRS: 0 Key check: Packet received on AWS

Test Case ID: LORA/EN/SEC/UUID/BV-01: End Node rotates UUID immediately after time sync

Attribute Value
Case ID C83934653
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Get initial TX UUID: print txid TXID: 0x<uuid> Key check: Note the UUID value
2 Wait for time sync EVENT SID STATUS: State: 0, Reg: 0, Time: 0, Link_Mask: 4 EVENT SID STATUS LINK MODE: LORA: 1, FSK: 0, BLE: 0 Key check: Time: 0 (time synced)
3 Get TX UUID again: print txid TXID: 0x<new_uuid> Key check: UUID is different from Step 1 (rotated after time sync)

Test Case ID: LORA/EN/SEC/UUID/BV-02: UUID rotates every 15 minutes after time sync

Attribute Value
Case ID C83934654
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Get initial TX UUID: print txid TXID: 0x<uuid> Key check: Note the UUID value
2 Monitor UUID rotation for 2 rounds. Check UUID every 30 seconds: print txid Round 1: UUID rotated after ~15 minutes. Round 2: UUID rotated after ~15 minutes. Key check: Each rotation within 14-16 minutes
3 Verify all collected UUIDs are unique All UUIDs are unique. Key check: No duplicate UUID detected

Test Case ID: LORA/EN/SEC/UUID/BV-03: End Node can exchange UL/DL during UUID rotation

Attribute Value
Case ID C83934655
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Get initial TX UUID: print txid TXID: 0x<uuid>
2 Wait for 1st UUID rotation (check every 30s): print txid TXID: 0x<new_uuid> Key check: UUID rotated (1st rotation detected)
3 Wait ~14 minutes, then send UL/DL continuously until 2nd UUID rotation: sid send <5-byte-payload> (UL) and send DL from AWS IoT (DL). After 2nd rotation, send one more UL/DL to confirm. UL: EVENT SID SEND STATUS: SID ERR: 0, TYPE: 2, ID: <id>, LINK: 4 LINK_MODE: 0 DL: EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: 5, LINK: 4, ... 2nd UUID rotation detected. UL/DL still works after rotation. Key check: UL/DL successful before and after UUID rotation

Test Case ID: LORA/EN/CONN/REG/BV-02: End Node can be deregistered from Sidewalk network

Attribute Value
Case ID C83934657
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Run the following command to deregister the device: sid factory_reset CMD: ERR: 0 EVENT SID STATUS: State: 1, Reg: 1, Time: 1, Link_Mask: 0 Key check: Reg: 1 (deregistered)

Test Case ID: LORA/EN/CONN/LP/BV-01: End Node can select Profile A and complete Join procedure

Attribute Value
Case ID C83934658
Executable by Customer Yes
Preconditions
  • sid option -lp_set 128 5
  • sid option -lp_get_l3
Test Steps
Step Description Expected Result
1 Initialize and start LoRa stack with Profile A: sid init 3 sid option -lp_set 128 5 sid start Each command returns: CMD: ERR: 0 EVENT SID STATUS: State: 0, Reg: 0, Time: 0, Link_Mask: 4 EVENT SID STATUS LINK MODE: LORA: 1, FSK: 0, BLE: 0 Njoin(1, 2) st 2->6 Key check: Time: 0 (time synced), join completed

Test Case ID: LORA/EN/CONN/LP/BV-02: End Node can select Profile B and complete Join procedure

Attribute Value
Case ID C83934659
Executable by Customer Yes
Preconditions
  • sid option -lp_set 129 0
  • sid option -lp_get_l3
Test Steps
Step Description Expected Result
1 Initialize and start LoRa stack with Profile B: sid init 3 sid option -lp_set 129 0 sid start Each command returns: CMD: ERR: 0 EVENT SID STATUS: State: 0, Reg: 0, Time: 0, Link_Mask: 4 EVENT SID STATUS LINK MODE: LORA: 1, FSK: 0, BLE: 0 Njoin(1, 2) st 2->6 Key check: Time: 0 (time synced), join completed

Attribute Value
Case ID C83934660
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Send 5 UL packets from EN with 10 byte payload: sid send <10-byte-payload> CMD: ERR: 0 TYPE: 2 ID: <id> EVENT SID SEND STATUS: SID ERR: 0, TYPE: 2, ID: <id>, LINK: 4 LINK_MODE: 0 ADDITIONAL ATTRS: 0 Key check: UL packets received on AWS

Attribute Value
Case ID C83934661
Executable by Customer Yes
Preconditions
  • The seq num field should be properly incremented by one for each subsequent packet sent by DUT within a maximum of 15 minutes from the previous UUID change, then a new sequence number should be generated in the range between 0 and 16383.
Test Steps
Step Description Expected Result
1 Send 1 UL packet: sid send TEST LoraTx:EnqPkt sqn:<seq> src_frmt:1 src_id:0x<txid> dst_frmt:0 dst_id:0x<gw_id> msg_id:<id> Key check: Note the SEQ number
2 Wait for UUID rotation (~15 minutes after time sync) UUID rotated (TX UUID changes)
3 Send 1 UL packet after UUID rotation: sid send TEST LoraTx:EnqPkt sqn:<new_seq> src_frmt:1 src_id:0x<new_txid> dst_frmt:0 dst_id:0x<gw_id> msg_id:<id> Key check: New SEQ number is different from Step 1 (reset after UUID change)

Attribute Value
Case ID C83934662
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Send 3 DL packets from AWS IoT with SEQ: 1, 2, 3 All 3 DL packets received and accepted by EN: EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: Delivery ratio 100%
2 Send 3 DL packets from AWS IoT with SEQ: 6, 5, 4 All 3 DL packets received and accepted by EN: EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: Delivery ratio 100%

Attribute Value
Case ID C83934663
Executable by Customer Yes
Preconditions
  • EN MCU <= 1.13
Test Steps
Step Description Expected Result
1 Send DL with SEQ=1, then send DL with SEQ=1 again (duplicate) First: EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... (accepted). Second: No EVENT SID RECEIVED within 20 seconds (duplicate rejected). Key check: Duplicate rejected
2 Send DL with SEQ=2, then send DL with SEQ=2 again (duplicate) First: EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... (accepted). Second: No EVENT SID RECEIVED within 20 seconds (duplicate rejected). Key check: Duplicate rejected

Attribute Value
Case ID C83934664
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Send 5 DL packets with SEQ: 1, 2, 3, 4, 5 EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: All 5 packets received
2 Send 5 DL packets with SEQ: 1, 2, 3, 4, 5 again (all duplicates) No EVENT SID RECEIVED for any packet. Key check: All duplicates rejected

Test Case ID: LORA/EN/CONN/SEQ/BV-07: SEQ number can be accepted again after getting 10 other messages

Attribute Value
Case ID C83934665
Executable by Customer Yes
Preconditions
  • EN MCU <= 1.13
  • Seq=1,2,3,4,5,6,7,8,9,10,11,1
Test Steps
Step Description Expected Result
1 Send 10 DL packets from AWS IoT with SEQ: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 All 10 DL packets received and accepted by EN. Delivery ratio 100%
2 Send 1 DL packet with SEQ=1 (duplicate) No EVENT SID RECEIVED within 20 seconds. Key check: Delivery ratio 0%
3 Send 1 DL packet with SEQ=11 (new, non-duplicate) EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: Delivery ratio 100%
4 Send 1 DL packet with SEQ=1 again (now outside the 10-SEQ window) EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: SEQ=1 accepted again after 10 other messages

Test Case ID: LORA/EN/CONN/SEQ/BV-08: SEQ number can be accepted again after End Node reinitialization

Attribute Value
Case ID C83934666
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Send DL packet with SEQ=1 EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: Packet accepted
2 Send DL packet with SEQ=1 again (duplicate) No EVENT SID RECEIVED within 20 seconds. Key check: Duplicate rejected
3 Reinitialize Sidewalk stack: sid stop sid deinit sid init 3 sid start Each command returns: CMD: ERR: 0 Wait for time sync: EVENT SID STATUS: State: 0, Reg: 0, Time: 0, Link_Mask: 4 Wait for join: Nsync st ->2
4 Send DL packet with SEQ=1 again (after reinit) EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: SEQ=1 accepted again after reinit

Test Case ID: LORA/EN/CONN/SEQ/BV-09: End Node drops the packet with SEQ which is out of range

Attribute Value
Case ID C83934667
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Send DL packet with SEQ=0 (minimum valid) EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: Accepted
2 Send DL packet with SEQ=16383 (maximum valid) EVENT SID RECEIVED: TYPE: <type>, ID: <id>, LEN: <len>, LINK: 4, ... Key check: Accepted
3 Send DL packet with SEQ=-1 (out of range) No EVENT SID RECEIVED within 20 seconds. Key check: Rejected (out of range)
4 Send DL packet with SEQ=16384 (out of range) No EVENT SID RECEIVED within 20 seconds. Key check: Rejected (out of range)

Test Case ID: LORA/EN/NW-SYNC/JOIN/BV-02: End Node keeps synchronization with the network by periodic transmission of Join request

Attribute Value
Case ID C83934668
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Initialize and start LoRa stack: sid init 3 sid start Wait for time sync and join Each command returns: CMD: ERR: 0 EVENT SID STATUS: State: 0, Reg: 0, Time: 0, Link_Mask: 4 Njoin(1, 2) st 2->6 Key check: Time synced and joined
2 Wait 14 minutes after time sync. Do not send any UL. No UL packets sent during this period
3 Wait for join response Njoin(1, 2) st 2->6 Key check: Join response received (periodic join request)

Test Case ID: LORA/EN/NW-SYNC/JOIN/BV-03: End Node keeps synchronization with the network by embedded sync request

Attribute Value
Case ID C83934669
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 EN time-sync and joined EN is time-synced and joined to the network
2 Wait 150 seconds, EN send a UL packet EN receives NTFY_JOIN_REQ
3 Wait 170 seconds EN does not send SET_JOIN_REQ in this period

Test Case ID: LORA/EN/NW-SYNC/TIME/BV-01: End Node completes the initial time sync procedure

Attribute Value
Case ID C83934670
Executable by Customer Yes
Test Steps
Step Description Expected Result
1 Reboot EN, then initialize and start LoRa stack: reboot sid init 3 sid start Wait for time sync Each command returns: CMD: ERR: 0 EVENT SID STATUS: State: 0, Reg: 0, Time: 0, Link_Mask: 4 EVENT SID STATUS LINK MODE: LORA: 1, FSK: 0, BLE: 0 Key check: Time: 0 (time synced)